DC12/AC24 Power SPD BOS12YM2

  • Video SPD BOS05B/JKM
  • Video SPD CoaxB/NM-F
  • Rs485 signal SPD BOS05YM2
  • DC12/AC24 Power SPD BOS12YM2
  • Audio / Tel SPD BOS110RJ11M2
  • Network RJ45 SPD BOS05RJ45M4
  • 2 in 1 SPD BOSJK2/DC12
  • 3 in 1 SPD BOSJK3/DC12
  • 4 / 8 chs video SPD CoaxJK/V4(V8)
  • Network & power 2 in 1 SPD RJ45/DC12

Product Abstract:

Reacting within Picosecond level; Maximum discharging current is 10KA


Product Description

 

Function:
       BOS12YM2 lightning protector is applied for protecting the sensitive signal equipments such as communication
 special lines, telesignalisations, telecontrol signals, etc. It is widely used for protecting data transmission in
 computer communication system, monitoring control system, entrance guard interphone system, PLC automatic
 control system, and fire prevention alarm system. It can avoid serious damage which made by thunder and lightning
 induced tension, electrical network voltage undulation disturbance, static discharge, and impact surge voltage.
 Typically used for lightning and surge protection
 
Feature:
  1. BOS12YM2 communication signal surge protector is designed according to the standard of IEC surge protector.
  2. The joint form is standard screw grip, it can protect 1~2 groups of circuits..
  3. There are various choices of quota voltage, also, the installation and maintenance is very easy and convenient.
  4. 3-levels series type, the Maximum discharging current can achieve 10kA, reacting within Picosecond level, it can
       fully protect those equipments which use the latest semiconductors
 
Specification:
  Model   BOS12YM2
  Continuous operating voltage Un   12V
  Nominal discharging current In (8/20us)   5KA
 Maximum discharging current Imax (8/20us)   10KA
  Limit voltage Up   15V
  Data transmission rate Vs   10Mbps
  Insert loss Ae   0.2dB
  Response time Ta   1nS
  Joint form   Grip
  Typically used in   12V lightning protection
  Protection form   Line to line, line to earth
  Dimension   25mm*25mm*54mm(does not include the joint)
  Working conditions   Temperature -25+65℃;Humidity95%25-30
  Expiration pattern  The communication lines are short-circuit or cut off to earth
  Test standard   IEC61643-21:2000
 
Installation and Maintenance:
  1.    The surge protector device should be linked between the signal line and the protected equipment.
         Connect manner is: 1 to 1, 2 to 2.(the follow picture is the example)
  2.   "In" must be connect the signal line;"Out" must be connect the protected equipment, do not connect in the
         opposite direction.
  3.    The PE line of the lightning arrestor must strictly be connected to the lighting protection system at the
         equipotential, else, it will influence the working performance.
  4.    Credibly connect the grounding lines. This product need not pay special attention to maintenance, but please 
         waterproof notice. When the system working goes wrong, please check the surge protector after removing it. If 
         unused thesurge protector condition,but the system working normal, meaning the surge protector is damaged,
         please change the surge protector.
 
The schematic diagram of installation:

 